2. Installation Instructions
2.1. DOS Installation
The DOS installation procedure consists of 2 steps after the PCI Quad RS232 card is inserted:
1. Determining the resources that the PCI Quad RS232 has claimed.
2. Informing the Serial Solutions DOS device driver of those resources.
Determining PCI Multiport Resources
Insert card into PC, as described in Chapter 2.
Run BBCARDS.EXE, from the supplied CD by typing the following:
A:\ >BBCARDS
Where A:\ is the drive containing the supplied file.
BBCARDS will return a string that looks similar to the following (values contained in the string may
differ in individuals PC’s due to resource availability):
PCI Quad Users:
Card 1 is on bus 0, device 16, function 0
Card ID=2, revision 3: Quad RS232
Interrupt line 11 has been assigned
4 sets of 16550-compatible registers are at I/O address 0140
SISR is at I/O address 0104
Baud clock control is at I/O address 02d0
Write 0xf6 for /8 (default), 0xf2 for /4, 0xd6 for /2, 0xd2 for /1.
Note down IRQ, I/O address and SISR (the SISR is the Shared Interrupt Status Register, which is a read
only register which returns an index value that identifies which port on the card has an interrupt awaiting
servicing by the driver software.) In this case:
The IRQ = 11
The I/O address = 0140
The SISR = 0104
NEWCOM.SYS Parameters
The NewCOM.SYS device driver included with the PCI Quad RS232 driver software is used to set up the
card in DOS and has the following syntax:
NEWCOM.SYS /A port address, /L SISR, IRQ, range /B number buffer /S buffer /H Hardware Handshake
Where /A port address specifies COM number followed by a hexadecimal address in the form /Axy where x
is COM port range and y is I/O address.
/L SISR, IRQ, range specifies SISR address, card interrupt and COM port range. The COM port(s).
Range may be a single port OR a range of ports.
/B number buffer is used to set the number of pairs of buffers to be allocated to ports and is a
decimal number in the range 1-maxport.